Related Experiment Video
Updated: Aug 8, 2026

Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
Mechanisms underlying overdrive suppression and overdrive excitation in guinea pig sino-atrial node
Adam T Graziani1, Mario Vassalle
1Department of Physiology and Pharmacology, State University of New York, Downstate Medical Center, 450 Clarkson Avenue, Box 31, Brooklyn, NY 11203, USA.
Abstract:
The hypothesis that the pause that follows overdrive of the sino-atrial node (SAN) might be the net result of overdrive excitation and overdrive suppression was tested by studying rate and force patterns induced by overdrive in isolated guinea pig SAN superfused in vitro. In Tyrode solution, the pause is short and changes but little with longer or faster drives. In high [K(+)](o) solution, longer overdrives increase force percent-wise more than in Tyrode solution, shorten the pause and are followed by greater rate and force. When the SAN (quiescent in high [K(+)](o)) is driven at 6/min, faster overdrives are followed by stronger, slowly decreasing contractions. Alternating 10 s drives with 10 s pauses have little effect on force and rate in Tyrode solution, but progressively increase force and rate in high [K(+)](o). Cesium has effects similar to high [K(+)](o). High [Ca(2+)](o) increases force and in high [K(+)](o) increases the rate as well as it shortens the pause, whereas Ni(2+) decreases force as well as rate and lengthens the pause. Barium dissociates the effects on force and rate. Lidocaine and tetrodotoxin decrease rate and force, and increase the pause duration. In overdrive excitation, the increase in rate is associated with an enhancement of diastolic voltage oscillations. It is concluded that in SAN the prevalence of Ca(2+) load leads to overdrive excitation whereas the prevalence of Na(+) load leads to overdrive suppression. In Tyrode solution, the pause after drive appears to be the net result of these two different mechanisms.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
G-Protein Gated Ion Channels
Sensory organs,...
Electrophysiology of Normal Cardiac Rhythm
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...