Related Experiment Video
Updated: Aug 8, 2026
![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)
Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941
Published on: April 28, 2019
[123I]TPCNE--a novel SPET tracer for the sigma-1 receptor: first human studies and in vivo haloperidol challenge
James M Stone1, Erik Arstad, Kjell Erlandsson
1Institute of Psychiatry, King's College London, London, UK. j.stone@iop.kcl.ac.uk
Abstract:
[123I]TPCNE (1(trans-[123I]iodopropen-2-yl)-4-[(4-cyanophenoxy)methyl] piperidine; Ki = 0.67 nM; log P = 3.36) is a novel sigma-1 receptor SPET ligand. In this study, we developed an optimized labeling method for [123I]TPCNE and investigated the kinetics, binding characteristics, and whole-body distribution of this tracer for the first time in humans. We also performed a challenge with the sigma-1 receptor antagonist haloperidol against [123I]TPCNE. Seven healthy volunteers were recruited. Dynamic brain SPET scans were performed following i.v. administration of 185 MBq [123I]TPCNE in all seven subjects. Three of the subjects were given oral haloperidol (2.5 mg) approximately 1 h before the scan. The dynamic data were analyzed with both reversible and irreversible compartmental models.[123I]TPCNE showed high uptake in brain and liver. All non-haloperidol-treated subjects showed a high whole-brain uptake (average: 8.7% of injected activity). No significant clearance of the tracer was seen up to 30 h post injection. In the haloperidol-treated subjects, the time-activity curves clearly demonstrated clearance of the tracer from the brain. Regional radioactivity concentrations were reduced by haloperidol from 42% in the cerebellum to 73% in the thalamus.[(123)I]TPCNE demonstrated high brain uptake, with highest binding found in the posterior cingulate. A region in which binding was unaffected by haloperidol pretreatment could not be identified, and the time-activity data were best described by an irreversible model.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...