Related Experiment Video
Updated: Jul 22, 2026

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
No confirmation of visual evoked potential diagnostic test for migraine
J G van Dijk1, M Dorresteijn, J Haan
1Department of Neurology/Clinical Neurophysiology, Leiden University Hospital, Netherlands.
Abstract:
We have attempted to replicate the results of studies on a diagnostic test reported to have 90% sensitivity and 89-96% specificity for migraine. The technique is based on peak-to-peak measurements of fast background electroencephalographic activity during a visual evoked potential (VEP) study. VEP latencies and amplitudes did not differ significantly, and showed substantial overlap, between a group of eight migraine patients and ten age-matched healthy controls. We could not recognise previously described fast activity or measure it objectively by peak-to-peak measurements. We cannot confirm that measurement of fast wave activity in the VEP background is useful in diagnosis of migraine.