Pilot measurements of ELF contact currents in some electric utility occupations

Joseph Bowman1, John Niple, Rob Kavet

  • 1NIOSH Physical Hazards Team, Engineering and Physical Hazards Branch, National Institute of Occupational Safety and Health, 4676 Columbia Parkway, Cincinnati, OH 45226, USA. jdb0@cdc.gov

Related Concept Videos

Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
Applications of EMF Measurements01:26

Applications of EMF Measurements

Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and the equilibrium...
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
Calculation of Electric Flux01:25

Calculation of Electric Flux

Consider the electric field of an oppositely charged, parallel-plate system and an imaginary box between those plates. Let the bottom face of the box be ABCD, and the top face be FGHK. The electric field between the plates is uniform and points from the positive plate toward the negative plate. The calculation of this field's flux through the box's various faces shows that the net flux through the box is zero. Why does the flux cancel out here?