Optical activity measurement by use of a balanced detector optical heterodyne interferometer

Chien Chou1, Hsiu-Ming Tsai, Kuan-Yung Liao

  • 1Institute of Biophotonics Engineering, National Yang Ming University, Taipei, Taiwan. cchou@ym.edu.tw

Applied Optics
|May 26, 2006
PubMed

Related Concept Videos

Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Properties of Enantiomers and Optical Activity02:24

Properties of Enantiomers and Optical Activity

It is essential to understand the difference between chiral and achiral interactions and the implications thereof in optical activity and their applications. Just as our feet, which are chiral, interact uniquely with chiral objects, such as a pair of shoes, but identically with achiral socks, enantiomers of a molecule exhibit different properties only when they interact with other chiral media. An example of a significant implication from this facet is the phenomenon known as optical activity,...
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...