Related Experiment Video
Updated: Aug 8, 2026

Hydrogel Nanoparticle Harvesting of Plasma or Urine for Detecting Low Abundance Proteins
Published on: August 7, 2014
Diagnostic aids for the detection of urine in the equine ejaculate
G C Althouse1, S W Seager, D D Varner
1Department of Veterinary Physiology & Pharmacology, Texas Veterinary Medical Center Texas A&M University College Station, TX 77843 USA.
Abstract:
An experiment was conducted to evaluate three commercially available test kits, the Azostix, Multistix and Uric-acid test, for the detection of urine in the equine ejaculate. Azostix, which tests for urea nitrogen, consistently detected urine in the equine ejaculate. Urine contamination was evident when a color change occurred in the reagent pad, going from yellow to green after 10 sec of exposure. The sensitivity of Azostix to urea nitrogen in contaminated samples was 39 mg/dl. The Multistix test kit also successfully detected urine in semen. In the Multistix nitrite pad the color changed from yellow to organge after 3.5 min of exposure to urine-contaminated semen. The Uricacid test kit did not accurately detect urine-contaminated samples. It constantly elicited false positive results in all the control trials. The results of this study show that Azostix and Multistix are cost effective ($1.25 per analysis) and accurate diagnostic aids for detecting urine in the stallion ejaculate.
Related Concept Videos
Urine Studies I: Urinalysis
Urine Studies II: Urine Culture and Sensitivity Test
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care