Background:
The success of a newly created arteriovenous fistula (AVF) depends on sufficient maturation of the forearm vein used. This maturation fails in up to 50%. We hypothesize that impairment of forearm venous distensibility, ie, the ability of veins to adjust to increased pressure, is related to AVF failure.
Methods:
Forearm venous distensibility was measured by using strain-gauge plethysmography in 27 patients with end-stage renal failure awaiting vascular access surgery; either AVF or graft (AVG) formation. Ultrasound duplex scanning of the upper-extremity circulation was performed 4 weeks before surgery. Failure to mature is defined as inability to use the AVF for hemodialysis within 8 weeks after surgery.
Results:
Venous distensibility in patients receiving an AVG (n = 10) was 0.44 +/- 0.05 mL/mm Hg, and in patients receiving an AVF (n =17), 0.56 +/- 0.04 mL/mm Hg (P = 0.2). Venous distensibility was 0.46 +/- 0.03 mL/mm Hg in patients with an unsuccessful AVF (n = 9) and 0.66 +/- 0.05 mL/mm Hg in patients with a successful AVF (n = 8; P = 0.003). All 7 patients with venous distensibility of 0.50 mL/mm Hg or less had a nonfunctional AVF (100%), whereas only 2 of 10 patients with venous distensibility greater than 0.50 mL/mm Hg had a nonfunctional AVF (20%; P = 0.002). No differences were found in arterial and venous luminal diameters between functional and nonfunctional AVFs.
Conclusion:
These preliminary results suggest that forearm venous distensibility is a predictor of AVF success, whereas luminal diameters are not. Measurement of venous distensibility may be helpful in choosing the most suitable access type for each individual patient, possibly improving access patency.
Related Concept Videos
Hemodialysis I: Introduction
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Arteries of the Upper Limbs
Pre-Procedural Guidelines for Assessing Blood Pressure