Evaluation of methanol-water and acetonitrile-water binary mixtures as eluents for temperature-dependent inclusion

Paweł K Zarzycki1, Elzbieta Włodarczyk, Da-Wei Lou

  • 1Laboratory of Toxicology, Department of Environmental Biology, Technical University of Koszalin, Poland. pkzarz@wp.pl

Related Concept Videos

High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
Phase Diagrams of Ternary Systems01:28

Phase Diagrams of Ternary Systems

Consider a ternary system, which is composed of three components: water (W), ethanoic acid (E), and trichloromethane (T). Here, Ethanoic acid (E) is fully miscible with both water (W) and trichloromethane (T), meaning it can mix entirely with either of them. However, water and trichloromethane have partial miscibility, meaning they can only mix to a certain extent, beyond which two separate phases will form.The phase diagram of a ternary system is represented as an equilateral triangle, where...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
Titration in Nonaqueous Solvents01:16

Titration in Nonaqueous Solvents

Most acid-base titrations are performed in an aqueous medium. In aqueous titrations, water competes with weaker acids or bases for proton donation or acceptance, leading to ambiguous endpoints in the titration curve. Water also affects the partial ionization of weak acids or bases. For example, water accepts a proton from acetic acid to form hydronium and acetate ions. The hydronium ion formed is a stronger acid than acetic acid, and the acetate ion is a stronger base than water. As a result,...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...