Electrical measurement of the absorption surfaces of tree roots by the earth impedance method: 1. Theory

Ludek Aubrecht1, Zdenek Stanek, Jan Koller

  • 1Department of Physics, CTU in Prague, Faculty of Electrical Engineering, Technicka 2, 166 27 Prague 6, Czech Republic. aubrecht@fel.cvut.cz

Tree Physiology
|June 3, 2006
PubMed

Related Concept Videos

RLC Series Circuits: Impedance01:29

RLC Series Circuits: Impedance

When current flow is opposed in a DC or AC circuit, it is referred to as resistance or impedance, respectively. Impedance plays a key role in determining the performance of AC circuits. It is represented by Z, which is a combination of resistance and reactance, and depends upon the angular frequency, measured in ohms.
Thus, the magnitude of the impedance is given by the following equation,
Bode Plots Construction01:24

Bode Plots Construction

The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
Impedance Combination01:21

Impedance Combination

Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the voltage division...
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Shunt Admittances01:26

Shunt Admittances

Shunt admittances play a crucial role in the analysis of transmission lines, particularly for three-phase systems with neutral conductors. When a uniformly charged conductor is positioned above the Earth, it induces an equal but opposite charge on its surface. This interaction creates electric field lines between the conductor and the Earth.
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Boundary Conditions: Lossless Lines01:21

Boundary Conditions: Lossless Lines

Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...