Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Impurities in a lyophilized formulation of BMS-204352: identification and role of sanitizing agents
Munir N Nassar1, Vishwas V Nesarikar, Nona Khaselev
1Biopharmaceutics Research and Development, Pharmaceutical Research Institute, Bristol-Myers Squibb, New Brunswick, NJ 08903, USA. nassarm@bms.com
Abstract:
The purpose of this study was to identify two impurities in the parenteral lyophilized formulation of BMS-204352, investigate the role of sanitizing agents as their potential source, evaluate their effect on drug product stability, and develop a strategy to prevent their contamination of the drug product. The two impurities were identified as o-phenylphenol and 4-t-amylphenol based on liquid chromatography/mass spectroscopy (LC/MS) and chromatographic comparison to authentic samples. The LC/MS spectra of commercially available o-phenylphenol and 4-t-amylphenol showed identical patterns of fragmentation and the same retention times as the impurities identified in the BMS-204352 lyophilized product. Levels of these impurities were low and ranged between 0.2-0.3 microg/vial as determined by HPLC and using an authentic external reference standard. To confirm the hypothesis that the commercial sanitizing agents used in the sterile area were the source of these phenolic impurities, several product samples were spiked with the sanitizing agents. Both o-phenylphenol and 4-t-amylphenol were detected in the spiked samples. Further investigation revealed that o-phenylphenol and 4-t-amylphenol are active ingredients of these commercial sanitizing agents. Drug product samples containing the phenolic impurities showed no potency loss following storage at 30, 50, and 70 degrees C indicating these impurities had no adverse effect on product stability. These studies suggest that sanitizing agents used in the sterile area, although may be present at trace levels below typical cleaning procedure detection methods, need to be properly controlled and closely monitored during the manufacturing of injectable products, particularly highly potent drugs. Sanitizing agents, even though not used on product contact surfaces, may potentially contaminate a product through vapor transfer in an open environment.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Radiation and Filtration