Related Experiment Video
Updated: Aug 8, 2026

Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Thermal monitoring: invasive, minimal-invasive and non-invasive approaches
Peter Wust1, Chie Hee Cho, Bert Hildebrandt
1Clinic for Radiation Medicine, Charité Medical School, Campus Virchow Klinikum, Berlin, Germany. peter.wust@charite.de
Background:
Thermal treatments need verification of effectiveness. Invasive intra-tumoural thermometry was established as a standard method several years ago. However, in deep heating, invasive techniques have disadvantages. Therefore, alternatives have been suggested and are under development.
Methods:
In three phase II studies treating rectal cancer, cervical cancer and prostate cancer, this study replaced invasive (intra-tumoural) thermometry by tumour-related reference points or catheter sections in the rectum, vagina or urethra. Index temperatures and thermal dose parameters were determined. Two recent studies treated patients with recurrent rectal cancer and soft tissue sarcoma using non-invasive MR-thermometry employing the SIGMA-Eye applicator. The proton resonance frequency shift (PRFS) method was employed to generate MR-temperature distributions during the entire heat treatment in 10 min intervals (via phase differences). Fat correction (nulling specified regions in the fat tissue) was utilized to calibrate the method, in particular with respect to the B0-drift.
Results:
Statistically significant correlations were found between response (downstaging, WHO) and thermal parameters in rectal cancer (37 patients, rectum measurement, T90, cum min T90 >or= 40.5 degrees C) and cervical cancer (30 patients, vagina, mean temperature and equ min 43 degrees C in a reference point). In prostate cancer (14 patients), a clear correlation was verified between long-term PSA control (
Conclusions:
For tumours in the pelvis and in the lower extremities, invasive measurements can be replaced by minimally-invasive or non-invasive techniques, which provide equivalent or even more complete information. Extending the application of these surveillance methods to abdominal tumours or liver metastases is a challenge, but strongly desirable for clinical reasons.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...