Related Experiment Video
Updated: Aug 3, 2026

Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
An electrocardiogram-based method for early detection of abrupt changes in blood pressure during hemodialysis
Kristian Solem1, Anders Nilsson, Leif Sörnmo
1Signal Processing Group, Department of Electroscience, Lund University, Lund, Sweden.
Abstract:
Clinical techniques for early detection of acute hypotension during conventional hemodialysis treatment are lacking, even though intradialytic hypotension is the most common acute complication. In this article, intradialytic hypotension is identified by means of signal analysis of data recorded at two clinics. The database consists of 30 treatments with concurrently acquired signals: the 12-lead electrocardiogram, continuous blood pressure, hematocrit, oxygen saturation, relative blood volume, and important hemodialysis variables. This article presents two characteristics, a heart rate turbulence (HRT) measure called turbulence slope (TS), and the LF/HF ratio, which provide information, at the beginning of hemodialysis treatment, on the patient's propensity to hypotension (TS: p = 0.0038, and LF/HF ratio: p = 0.0028). The authors also present a novel dynamic echocardiography-based method for detecting intradialytic hypotension using complementary information on heart rate variability (HRV) and ectopic beat patterns. These two types of information reflect different mechanisms of cardiac activity. It is essential that both types are used for the detection of hypotension, because HRV analysis is inappropriate when several ectopic beats are present. The proposed dynamic echocardiography-based method offers early identification of the cases with acute intradialytic hypotension of the database.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.