Related Experiment Video
Updated: Aug 7, 2026

High-resolution In Vivo Manual Segmentation Protocol for Human Hippocampal Subfields Using 3T Magnetic Resonance Imaging
Published on: November 10, 2015
Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus
Talaignair N Venkatraman1, Robert M Hamer, Diana O Perkins
1Brain Imaging and Analysis Center, Duke University Medical Center, Durham, NC 27710, USA.
Abstract:
The precision [coefficient of variation or CV (%) = 100SD/X] of single-voxel point resolved spectroscopic data was characterized bilaterally, in anterior cingulate and in hippocampus, at 4.0 T in a healthy subject. Data acquisition was replicated 10 times after voxel repositioning and readjusting higher order shims. Precision measurements show that the scan-to-scan precision is better in anterior cingulate than in hippocampus, with an average CV of 9.2% (for total NAA, tCho and Cr) in anterior cingulate and 13.9% in hippocampus. Variability measurements made by the same method in 24 healthy subjects and in 29 schizophrenia patients showed that there is substantial biological variability in metabolite levels, even in healthy subjects. Simple calculations suggest that more than 200 subjects would be needed to detect a 5% difference in NAA between patients and controls.