Influence of crank rate on the slow component of pulmonary O(2) uptake during heavy arm-crank exercise
Paul M Smith1, Eilidh McCrindle, Mike Doherty
1Centre for Sport and Exercise Science, University of Greenwich, Chatham, UK. p.m.smith@gre.ac.uk
Abstract:
The principal aim of this study was to examine the influence of variations in crank rate on the slow component of the pulmonary oxygen uptake ((.)VO(2)) response to heavy-intensity arm-crank ergometry (ACE). We hypothesized that, for the same external work rate, a higher crank rate would elicit a greater amplitude of the (.)VO(2) "slow component". Eleven healthy males (mean (+/- SD) age, 25 ((+/-6) y; body mass, 89.1 ((+/-10.7) kg; ACE (.)VO(2)(peak), 3.36 ((+/-0.47) L x min(-1)) volunteered to participate. The subjects initially completed an incremental exercise test for the determination of (.)VO(2)(peak) and peak power on an electrically braked arm ergometer. Subsequently, they completed "step" transitions from an unloaded baseline to a work rate requiring 70% of peak power: 2 at a crank rate of 50 r x min(-1) (LO) and 2 at a crank rate of 90 r x min(-1) (HI). Pulmonary gas exchange was measured on a breath-by-breath basis and (.)VO(2) kinetics were evaluated from the mean response to each condition using non-linear regression techniques. In contradiction to our hypothesis, the (.)VO(2) slow component was significantly greater at 50 r x min(-1) than at 90 r x min(-1) (LO: 0.60 +/- 0.30 vs. HI: 0.47 +/- 0.21 L x min(-1); p < 0.05). The mean value for the localized rating of perceived exertion was also higher at 50 r x min(-1) than at 90 r x min(-1) (LO: 16.7 +/- 1.4 vs. HI: 15.2 +/- 1.3; p < 0.05), but there was no significant difference in end-exercise blood lactate concentration. It is possible that differences in muscle tension development and blood flow resulted in a greater contribution of "low-efficiency" type II muscle fibres to force production at the lower crank rate in ACE, and that this was linked to the greater (.)VO(2) slow component. However, other factors such as greater isometric contraction of the muscles of the trunk and legs at the lower crank rate might also be implicated.
More Related Videos
07:32Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Pulmonary Cycle: Exhalation
Lung Capacity
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation