Related Experiment Video
Updated: Aug 7, 2026

In Situ Neutron Powder Diffraction Using Custom-made Lithium-ion Batteries
Published on: November 10, 2014
Corrections to refractive index data of stoichiometric lithium tantalate in the 5-6 microm range
V Z Kolev1, M W Duering, B Luther-Davies
1Laser Physics Centre, Research School of Physical Sciences and Engineering, The Australian National University, Canberra, Australian Capital Territory 0200, Australia. vesselin.kolev@anu.edu.au
Abstract:
We propose corrections to the coefficients in the published Sellmeier equation for stoichiometric LiTaO3 [Opt. Lett.28, 194 (2003)] that allow the extension of the wavelength range within the region of midinfrared absorption edge up to 6 microm. The required extraordinary refractive index data for this range were obtained using single-pass optical parametric fluorescence measurements with a pump wavelength of 1064.4 nm. We also observed efficient parasitic second-harmonic generation that could affect some quasi-phase-matching interactions. The corrected Sellmeier equation improves the accuracy of poling period calculations where the idler wavelength is within the region.