Pulse sounds and measurement of diastolic blood pressure in children

M Uhari1, M Nuutinen, J Turtinen

  • 1Department of Paediatrics, University of Oulu, Finland.

PubMed

Insights

Measuring diastolic blood pressure (BP) in children is debated, specifically using Korotkoff

Area of Science:

  • Pediatrics
  • Cardiovascular Health
  • Clinical Measurement

Background:

  • Diastolic blood pressure (BP) measurement in children lacks consensus regarding optimal auscultatory phase.
  • Korotkoff's fourth phase (K4) and fifth phase (K5) are debated indicators for diastolic BP in pediatric populations.

Purpose of the Study:

  • To evaluate the reliability and consistency of Korotkoff's fourth phase (K4) versus fifth phase (K5) for measuring diastolic blood pressure (BP) in children.
  • To determine the optimal auscultatory phase for accurate and repeatable diastolic BP measurements in pediatric age groups.

Main Methods:

  • Longitudinal study of 3012 Finnish children (aged 6-18 years) with repeated BP measurements in 1980, 1983, and 1986.
  • BP measured using mercury and random-zero sphygmomanometers, assessing the presence and difference between K4 and K5 diastolic BP.
  • Analysis of K4 and K5 absence rates and the correlation between the two phases across different age groups.

Main Results:

  • Korotkoff's fourth phase (K4) was consistently absent in 3.2% to 6.2% of children, while Korotkoff's fifth phase (K5) was absent in only 0.2% to 0.6%.
  • The difference between mean K4 and K5 diastolic BP ranged from 6.5 to 9.2 mm Hg, varying with age.
  • Both K4 and K5 diastolic BP measurements demonstrated good correlation across all pediatric age groups.

Conclusions:

  • Korotkoff's fifth phase (K5) is a more reliable and consistently obtainable indicator for diastolic blood pressure (BP) measurement in children.
  • Utilizing K5 for diastolic BP measurement ensures more reliable and repeatable assessments across all pediatric age groups, addressing measurement controversies.

Related Concept Videos

Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: