Related Experiment Video
Updated: Aug 7, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Skin entrance radiation dose in an interventional radiology procedure
Robert Y L Chu1, George Thomas, Feroz Maqbool
1Department of Radiological Sciences, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73190, USA. robert-chu@ouhsc.edu
Abstract:
Monitoring of skin entrance radiation exposure in lengthy interventional procedures has been recommended because of the potential for skin injury. Fluoroscopy duration and dose-area product (DAP) are readily available real-time measurements. It would be of interest to study the correlation of these parameters and skin entrance radiation. Twenty neurological interventional procedures performed through the aortic arch were monitored. Two pieces of GafChromic XR Type R film were placed between the patient and the examination table. An observer recorded the fluoroscopy duration and DAP for each phase of the procedure. Each film was scanned post-procedure in RBG mode, and then the image was analyzed for peak skin entrance radiation dose (in air kerma). All DAP values were corrected according to a calibration with an ion chamber. With the DAP values for the respective phases of a procedure, the effective dose in a Reference Man was calculated. For these twenty cases, the means and standard deviations were 17.2+/-6.4 min for x ray on-time, 256+/-65 Gy cm (-2) for DAP, 94+/-34 cGy for peak skin entrance dose in air kerma, and 19.2+/-5.0 mSv for effective dose, respectively. The peak skin entrance dose was correlated to fluoroscopy duration, DAP, and effective dose with the r(2)-values of 0.48, 0.46, and 0.09, respectively. The correlation with DAP or fluoroscopy duration was not sufficiently strong to infer skin entrance dose from either of these parameters. Therefore, skin entrance dose should be determined directly.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Endoscopic Procedures V: ERCP
Patient...
