Introduction:
We studied the efficiency of liquid cooling garments (LCG) and their relationship to the insulation of outer clothing, perfusate inlet temperatures, and environmental conditions by both theoretical analysis and thermal manikin (TM) testing.
Methods:
An equation to estimate LCG cooling efficiency was developed on the basis of energy balance. Cooling efficiency is a function of the thermal resistance between the TM skin and perfusate in the LCG, the thermal resistance between the environment and the perfusate, and TM skin, ambient, and perfusate temperatures. Three ensembles, a cooling vest (CV) only, CV plus a battle dress uniform (CVB), and CVB plus a battle dress overgarment (CVO), were tested on a sweating TM in dry and wet conditions. The TM surface temperature was maintained at 33 degrees C and the environment was 30 degrees C and 50% RH. The LCG heat removal from the TM was calculated using the power inputs to the TM with and without perfusate flow.
Results:
The cooling efficiency was increased from approximately 0.45 for CV to approximately 0.70 for CVO in dry experiments and from approximately 0.53 for CV to 0.78 for CVO in wet experiments.
Conclusion:
With additional outer clothing layers, higher thermal resistances increased the rate of heat removal from the TM surface, and decreased heat gain from the ambient environment, thus increasing efficiency. The perfusate inlet temperature had minimal influence on the efficiency. The equations developed can predict cooling efficiency and heat removal rates under a wider range of environmental conditions.
Related Concept Videos
Mechanism of heat transfer
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Mechanisms of Heat Transfer I
Mechanisms of Heat Transfer II
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant heat.