Relation of QT interval measurements to evolving automated algorithms from different manufacturers of
Paul Kligfield1, E William Hancock, Eric D Helfenbein
1Division of Cardiology, Weill Medical College of Cornell University, New York, New York, USA. pkligfi@med.cornell.edu
Abstract:
QT-interval measurements have clinical importance for the electrocardiographic recognition of congenital and acquired heart disease and as markers of arrhythmogenic risk during drug therapy, but software algorithms for the automated measurement of electrocardiographic durations differ among manufacturers and evolve within manufacturers. To compare automated QT-interval measurements, simultaneous paired electrocardiograms were obtained in 218 subjects using digital recorders from the 2 major manufacturers of electrocardiographs used in the United States and analyzed by 2 currently used versions of each manufacturer's software. The 4 automated QT and QTc durations were examined by repeated-measures analysis of variance with post hoc testing. Significantly larger automated QT-interval measurements were found with the most recent software of each manufacturer (12- to 24-ms mean differences from earlier algorithms). Systematic differences in QT measurements between manufacturers were significant for the earlier algorithms (11-ms mean difference) but not for the most recent software (1.3-ms mean difference). Similar relations were found for the rate-corrected QTc, with large mean differences between earlier and later algorithms (15 to 26 ms). Although there was a <2-ms mean difference between the most recent automated QTc measurements of the 2 manufacturers, the SD of the difference was 12 ms. In conclusion, reference values for automated electrocardiographic intervals and serial QT measurements vary among electrocardiographs and analysis software. Technically based differences in automated QT and QTc measurements must be considered when these intervals are used as markers of heart disease, prognosis, or arrhythmogenic risk.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias