Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Dosimetric properties of the liquid ionization chamber electronic portal imaging device (EPID)
Kunihiko Tateoka1, Atsushi Ouchi, Masaaki Waka
1Radiation Oncology, Imaging and Diagnosis, Molecular and Organ Regulation, Sapporo Medical University, Graduate School of Medicine, 291, Minai-1-jo Nishi-16-chome, Chuo-ku, Sapporo, 060-8543, Japan. tateoka@sapmed.ac.jp.
Abstract:
In the relation between the pixel values of the electronic portal imaging device (EPID) and dose rate, pixel values have been reported to be proportional to the square roots of the dose rates although some researchers have reported that each EPID pixel value was almost proportional to the dose rates when they were more than 1 Gy/min. To resolve this contradiction, in this study we have investigated the dosimetric properties of the liquid ionization chamber EPID based on a two-dimensional matrix of liquid- filled ionization chambers. Our results show that the pixel values of this EPID were proportional to the square roots of the dose rates when they were less than 0.5 Gy/min, and the values were proportional to the dose rates when they were more than that. In addition, the survival time of electrons in the liquid of the EPID is reportedly dependent on the amount of impurities in the liquid ionizing chamber of EPID. The pixel values of the EPID acquired in rapid succession, increased. In the results, the pixel values were constantly increased to approximately 0.2% of pre-images for less than 15 s of the rest interval. When changes in the sensitivity of each pixel value were approximately 1%, approximately 5% changes were observed against the transformed dose rate. To avoid this difference, we developed the following formula relating the pixel value, P, and dose rate, D. P=a D + b radicalD - k h (a, b, h: constants, k : variable).
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview