Objective:
To improve the method for preparing rabbit VX2 liver tumor model and observe the magnetic resonance imaging (MRI) features of the implanted tumors.
Methods:
Sixteen adult New Zealand white rabbits were assigned randomly into 4 equal groups, and VX2 tumor tissues were implanted into the right and left liver lobes with spiral CT guidance. Plain and contrast-enhanced MR scan and pathological analysis were performed in different stages (14, 18, 22 and 26 days) after tumor implantation.
Results:
Tumor implantation was successful in all the rabbits, and 18 to 22 days after tumor implantation, the diameters of the tumor ranged from 1 to 2 cm, which allowed observation and study. In plain MR scans, lower or equivalent tumor signal in comparison with hepatic parenchyma was observed, and contrast-enhanced scans produced obvious enhancement of the tumor edges. At 22 days after tumor implantation, obvious necrosis was observed in the center of the tumor.
Conclusion:
This method of preparing rabbit VX2 liver tumor model with spiral CT guidance is simple and convenient, and the tumors can be observed effectively with dynamic plain and contrast-enhanced MR scans.