Related Experiment Video
Updated: Aug 7, 2026

Phase-Resolved Functional Lung MRI for Pulmonary Ventilation and Perfusion (V/Q) Assessment
Published on: August 9, 2024
Fetal lung volume measurements: determination with MR imaging--effect of various factors
Valerie L Ward1, Mizuki Nishino, Hiroto Hatabu
1Department of Radiology, Children's Hospital, Harvard Medical School, 300 Longwood Ave, Boston, MA 02115, USA. valerie.ward@childrens.harvard.edu
Purpose:
To retrospectively determine the effect of gestational age (GA), imaging plane, section thickness, and inter- and intraobserver variability on fetal lung volume (FLV) measurements obtained with magnetic resonance (MR) imaging in a cohort of fetuses without thoracic abnormalities.
Materials And Methods:
Institutional review board approval was obtained. Informed consent for this retrospective cohort study was waived, and the conduct of this study was HIPAA compliant. FLV was measured in 30 fetuses (GA, 17-36 weeks) referred for MR imaging for indications other than pulmonary abnormalities. Measurements were made on single-shot fast spin-echo images by tracing free-form regions of interest on individual consecutive sections in the transverse, sagittal, and coronal planes. Measurements were performed twice by two observers independently. Correlations between FLV and GA, imaging plane, and section thickness were assessed, as were intra- and interobserver variability. Time to perform FLV was assessed in a subset of fetuses.
Results:
Total FLV ranged from 2 to 110 mL. Mixed-effects regression model showed significant quadratic trend in FLV with increasing GA, with comparable strength of correlation (r = 0.89-0.91) in the three imaging planes of measurement. Intraobserver agreement was good in all three planes (r = 0.65-0.83) and was highest in the transverse plane. Interobserver agreement was good in all three planes (r = 0.68-0.76). FLV showed no significant dependence on section thickness (P = .23) or imaging plane (P = .82). Mean time to obtain FLV measurements ranged from 48 seconds at GA of 21 weeks to 77 seconds at GA of 29-30 weeks.
Conclusion:
GA-based FLV measurements obtained with MR images are independent of section thickness and imaging plane and can be performed with good inter- and intraobserver agreement in less than 2 minutes.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...