This study introduces targeted-HASTE, a novel MRI technique for real-time visualization of percutaneous interventions. It enables precise needle guidance with 1-second temporal resolution, even with metallic components.
Area of Science:
- Magnetic Resonance Imaging
- Medical Interventions
- Biomedical Engineering
Background:
- Percutaneous MR-guided interventions necessitate rapid imaging sequences to visualize needle trajectories accurately.
- Minimizing susceptibility artifacts is crucial for effective real-time guidance during interventions.
- Existing fast imaging techniques like RARE and HASTE face challenges in achieving sufficient speed and artifact reduction.
Purpose of the Study:
- To develop an advanced Half-Fourier Acquisition Single-shot Turbo Spin-Echo (HASTE) pulse sequence for enhanced MR-guided interventions.
- To reduce scan time and focus imaging on the needle trajectory using inner-volume excitation (targeted-HASTE).
- To improve needle localization accuracy and real-time visualization during percutaneous procedures.
Main Methods:
- Implementation of a targeted-HASTE pulse sequence with inner-volume excitation to limit the field of view (FOV).
- Integration of a magnetization restore pulse (driven equilibrium Fourier transform (DEFT)) to counteract signal saturation.
- Combination with active marker coils for automated repositioning of the targeted-HASTE slice based on needle position and orientation.
- Utilizing an MR-compatible robotic assistance system for interventional procedures in animal experiments.
Main Results:
- Demonstrated visualization of needle insertion and infusion with a temporal resolution of 1 second.
- Successful localization of the needle tip, even in the presence of a stainless steel mandrel, indicating robustness to artifacts.
- Validation of the targeted-HASTE sequence and active marker coil system in an animal model.
Conclusions:
- The developed targeted-HASTE sequence significantly enhances real-time visualization for MR-guided interventions.
- The system allows for precise needle guidance and localization, improving procedural accuracy and safety.
- This technique shows promise for various percutaneous interventions requiring high temporal and spatial resolution under MRI guidance.
More Related Videos
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020
08:37Focused Ultrasound Induced Blood-Brain Barrier Opening for Targeting Brain Structures and Evaluating Chemogenetic Neuromodulation
Published on: December 22, 2020
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI