[Examination of attenuation correction using low-dose computed tomography].

Harumi Iguchi1, Tetsuo Kida, Kazuo Noma

  • 1Department of Radiology, Shiga University of Medical Science.

Nihon Hoshasen Gijutsu Gakkai Zasshi
|June 27, 2006
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Comparative Evaluation of Encoder- and Decoder-Based Models for Actionable Findings in CT Reports.

Journal of imaging informatics in medicine·2026
Same author

Multicentre survey of diagnostic reference levels for single-photon emission computed tomography/computed tomography and PET/computed tomography examinations at Japanese National University Hospitals: a comparative international analysis.

Nuclear medicine communications·2026
Same author

Robustness of heart dose against cardiac cycle in breast cancer radiotherapy with deep inspiration breath-hold.

Radiological physics and technology·2026
Same author

Temporal dynamics of somatosensory gating and facilitation in the primary somatosensory cortex during finger movements.

Cerebral cortex (New York, N.Y. : 1991)·2025
Same author

[Primary Lung Cancer that Developed Lung Abscess after Bronchoscopy and Was Cured by Surgery:Report of a Case].

Kyobu geka. The Japanese journal of thoracic surgery·2025
Same author

Evaluation of a retrieval-augmented generation system using a Japanese Institutional Nuclear Medicine Manual and large language model-automated scoring.

Radiological physics and technology·2025

Low-dose CT effectively corrects SPECT images, matching clinical dose results. Tailored attenuation correction maps improve accuracy for SPECT imaging.

Area of Science:

  • Nuclear Medicine
  • Medical Imaging
  • Radiology

Context:

  • Accurate SPECT image reconstruction requires attenuation correction.
  • X-ray CT-based attenuation correction is effective for non-uniform attenuation.
  • Optimizing CT scanning conditions is crucial for effective SPECT attenuation correction.

Purpose:

  • To evaluate the impact of varying CT scanning parameters on SPECT image attenuation correction.
  • To assess the feasibility of using low-dose CT for SPECT attenuation correction.
  • To compare attenuation correction efficacy between low-dose and clinical-dose CT.

Summary:

  • SPECT phantom scans were performed using CT at various kVp and mAs settings.
  • Attenuation correction equations derived from Hounsfield Units showed minimal variation across CT conditions.

Related Experiment Videos

  • Low-dose CT attenuation correction demonstrated comparable results to clinical-dose CT.
  • Impact:

    • Low-dose CT can be reliably used for SPECT attenuation correction, reducing radiation exposure.
    • Developing radionuclide-specific attenuation correction equations and maps enhances SPECT imaging accuracy.
    • Findings suggest improved SPECT image quality and diagnostic confidence with optimized attenuation correction.