Related Experiment Video
Updated: Aug 7, 2026

Design and Development of a Model to Study the Effect of Supplemental Oxygen on the Cystic Fibrosis Airway Microbiome
Published on: August 3, 2021
Effects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in
Thomas P Knowles1, Rory A Mullin, Jefferson A Hunter
1Cardiothoracic Anesthesia Department, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA. knowlet@ccf.org
Background:
The practice of on-ice storage of arterial-blood samples in plastic syringes for delayed analysis continues, and the effects of storage time and temperature on the measurement of blood-oxygen-saturation values (S(aO2)) have not been adequately described.
Objective:
To determine the effects of syringe material, storage time, and storage temperature on normal arterialized blood gas and S(aO2) values.
Methods:
We used a temperature-controlled extracorporeal circuit to "arterialize" 500 mL of fresh, whole human blood at 37 degrees C, and we used certified calibration gases of 12% O2 and 5% CO2 to produce normal blood-gas values. From that arterialized blood we took 90 samples and randomly assigned them to 6 groups, until there were 15 samples in each group. The groups were (1) plastic syringe, analyzed immediately, (2) plastic syringe, stored 30 min at 0-4 degrees C, (3) plastic syringe, stored 30 min at 22 degrees C, (4) glass syringe, analyzed immediately, (5) glass syringe, stored 30 min at 0-4 degrees C, and (6) glass syringe, stored 30 min at 22 degrees C.
Results:
Compared to the samples that were analyzed immediately, the P(O2) of the samples stored in plastic syringes for 30 min at 22 degrees C and at 0-4 degrees C was significantly higher, with a clinically important magnitude of 11.9-13.7 mm Hg. The P(CO2) of blood stored in glass for 30 min at 0-4 degrees C was significantly lower, although the magnitude of the difference (1.5 mm Hg) was not clinically important. There were no statistically significant differences in pH or oxygen saturation among the 6 groups.
Conclusion:
For accurate arterial-blood-gas results, samples drawn in plastic syringes should be analyzed immediately. If the analysis is going to be delayed, the samples should be drawn and stored in glass.
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Transport in the Blood
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.

