Resonance method of electric-dipole-moment measurements in storage rings

Yuri F Orlov1, William M Morse, Yannis K Semertzidis

  • 1Brookhaven National Laboratory, Upton, New York 11973, USA.

Related Concept Videos

Electric Dipoles and Dipole Moment01:30

Electric Dipoles and Dipole Moment

Consider two charges of equal magnitude but opposite signs. If they cannot be separated by an external electric field, the system is called a permanent dipole. For example, the water molecule is a dipole, making it a good solvent.
Theoretically, studying electric dipoles leads to understanding why the resultant electric forces around us are weak. Since electric forces are strong, remnant net charges are rare. Hence, the interaction between dipoles helps us understand electrical interactions in...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Induced Electric Dipoles01:29

Induced Electric Dipoles

A permanent electric dipole orients itself along an external electric field. This rotation can be quantified by defining the potential energy because the external torque does work in rotating it. Then, the potential energy is minimum at the parallel configuration and maximum at the antiparallel configuration. While the former is a stable equilibrium, the latter is an unstable equilibrium.
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis. This...
IR Spectrum Peak Intensity: Dipole Moment01:20

IR Spectrum Peak Intensity: Dipole Moment

The dipole moment of a bond is the product of the partial charge on either atom and the distance between them. Dipole moments influence the efficiency of IR absorption and the peak intensity. When a bond with a dipole moment is placed in an electric field, the direction of the field determines if the bond is compressed or stretched. Electromagnetic radiation consists of an electric field component that rapidly reverses direction. It follows that polar bonds are alternately stretched and...