S L Fessia1, R S Grabowy, G G Bousquet
1Department of Microbiology, University of Lowell, MA.
Abstract:
Studies were performed to quantify the microbial population reduction achieved with the Peritoneal Dialysis Moist Heat Device (PDM-1). This microwave method is used to disinfect the inner lumen of connectors used in the exchange process for continuous ambulatory peritoneal dialysis (CAPD). The microwave heating technique was evaluated on different connector systems containing a suspension of 10(6) microorganisms. The most prevalent and most problematic peritonitis-causative microorganisms were tested. After heating, the degree of disinfection was measured by enumerating bacterial colonies of the treated suspension. D-value determinations were then performed. The D-value for spores of A. niger was found to be 7.1 seconds for one type of connector system. Two other connector systems containing different intraluminal solution volumes were also tested using spores of A. niger and D-values were determined to be 7.6 seconds and 9.5 seconds, respectively. Other organisms tested were determined to have D-value times shorter than that for A. niger. Rapid heating of the solution contained within the CAPD connectors is a key characteristic of the microwave technique since temperatures rise high enough for destruction of microorganisms while leaving the plastic safe to touch. Thus, this technique is a safe and effective method for providing intraluminal disinfection.
More Related Videos
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Antimicrobial Effectiveness