Related Experiment Video
Updated: Aug 7, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Detection and characterization of metabolites in biological matrices using mass defect filtering of liquid
Mingshe Zhu1, Li Ma, Donglu Zhang
1Pharmaceutical Candidate Optimization, Bristol-Myers Squibb Pharmaceutical Research Institute, Princeton, NJ, USA.
Abstract:
An improved mass defect filter (MDF) method employing both drug and core structure filter templates was applied to the processing of high resolution liquid chromatography/mass spectrometry (LC/MS) data for the detection and structural characterization of oxidative metabolites with mass defects similar to or significantly different from those of the parent drugs. The effectiveness of this approach was investigated using nefazodone as a model compound, which is known to undergo multiple common and uncommon oxidative reactions. Through the selective removal of all ions that fall outside of the preset filter windows, the MDF process facilitated the detection of all 14 nefazodone metabolites presented in human liver microsomes in the MDF-filtered chromatograms. The capability of the MDF approach to remove endogenous interferences from more complex biological matrices was examined by analyzing omeprazole metabolites in human plasma. The unprocessed mass chromatogram showed no distinct indication of metabolite peaks; however, after MDF processing, the metabolite peaks were easily identified in the chromatogram. Compared with precursor ion scan and neutral loss scan techniques, the MDF approach was shown to be more effective for the detection of metabolites in a complex matrix. The comprehensive metabolite detection capability of the MDF approach, together with accurate mass determination, makes high resolution LC/MS a useful tool for the screening and identification of both common and uncommon drug metabolites.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrum: Interpretation