Related Experiment Video
Updated: Aug 7, 2026

Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia
Published on: September 20, 2015
Blood oxygen level-dependent (BOLD) magnetic resonance imaging in patients with dypiridamole induced ischaemia; a PET
M Egred1, G D Waiter, S I K Semple
1Cardiology Department, Cardio-thoracic Centre, Thomas Drive, Liverpool L14 3PE, UK. m.egred@ctc.nhs.uk
Background:
Blood oxygen level-dependent (BOLD) MRI relies on changes in deoxyhaemoglobin level in tissues under stress for signal variation and may be used for detection of ischaemic myocardium.
Methods:
15 patients with stress induced myocardial ischaemia on PET scanning underwent rest and dypiridamole stress MRI using a double breath-hold T2-weighted, ECG gated sequence to produce BOLD contrast images and cine-MRI for wall thickening assessment. Signal change on BOLD MRI and wall thickening were compared between rest and stress images in ischaemic and non-ischaemic myocardial segments.
Results:
Using PET, 156 segments were identified with reversible ischaemia and 324 as non-ischaemic. The ischaemic segments were found on BOLD MRI to have an average signal change between rest and stress of -16.7% compared to -14% in the non-ischaemic segments (p=0.04). The average wall thickening was 7.8 mm in the ischaemic segments compared with 9.5 mm in the non-ischaemic segments (p<0.0001).
Conclusion:
BOLD MRI with wall thickening assessment may differentiate ischaemic from non-ischaemic myocardium in patients with stress induced myocardial ischaemia. Larger studies with improved spatial resolution would help define a threshold for detection of ischaemia as well as determine this technique's sensitivity and specificity.