Related Experiment Video
Updated: Aug 7, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Devices used to humidify respired gases
1Department of Anaesthesiology and Intensive Care Medicine, Albertinen-Hospital, Süntelstrasse 11 A, D-22 457 Hamburg, Germany. joerg.rathgeber@albertinen.de
Abstract:
The efficiency of HMEs decreases with increasing tidal volumes. HMEs always result in an elevation of the inspiratory and expiratory airway resistances; this should be considered especially in cases that involve spontaneous respiration. The pressure drop across HMEs should be less than 2 hPa for a flow of 60 L/min, a level that also has been measured for cascade humidifiers.HMEs with a hygroscopic coating of CaCl2 should be given preference over LiCl-coated ones, especially because products of the same efficiency are available with CaCl2 coating. Lithium is a potentially toxic substance that can be taken up by way of bronchopulmonary resorption after accidental washing out [37]. Therefore, a possible safety hazard cannot be eliminated, especially in neonates and babies. Not least for these reasons HMEs must never be combined with active humidification systems or medication nebulizers. Even if the reduction in functional efficiency of the HME that is caused by washing off of the coating of hygroscopic substances is disregarded, the presence of medication aerosols in the HME, in particular, can result in a dangerous increase in resistance to gas flow. The internal volumes of HMEs should be as small as possible so that they do not increase the effective deadspace too much. A combination of HMEsand catheter mounts results in a further increase in the deadspace, and there-fore, must be considered critically, especially in cases that involve spontaneous respiration. If a catheter mount is necessary to add flexibility to the breathing system, the HME preferably should be connected directly onto the tracheal tube with the catheter mount behind it; otherwise, the humidification efficiency of the HME will be reduced by condensation in the catheter mount. Children should be ventilated with special HMEs that have a small internal volume. Caution is required in patients who have elevated sputum production, pulmonary trauma with bleeding, pulmonary edema, or a similar condition;in such patients a partial obstruction of the HME with a resulting elevation of the airway resistances might occur. In patients who have very viscous secretions (eg, as a result of a primary pulmonary disease or long-term dehydration therapy), heated humidifiers with a set temperature of greater than 370 degrees C should be given preference. Several recent investigations showed that not every device that is designated as an HME is appropriate for conditioning respiratory gases (ie, it effectively humidifies the inspiratory air). Most of the products that are available on the market are, at best, adequate for anesthetic ventilation or short-term postoperative follow-up ventilation. Generally, this is true of all HMEs that have not been coated with hygroscopic substances. CoatedHMEs have a much better humidification efficiency; however, here too, the existence of substantial differences in quality among the products prohibits an uncritical application.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
