Iron indices: what do they really mean?

D Coyne1

  • 1Washington University School of Medicine, 600 South Euclid Ave., Campus Box 8129, St Louis, Missouri 63110, USA. dcoyne@im.wustl.edu

Routine monitoring of body iron stores is an essential component of overall management for the patient on hemodialysis. Adequate iron levels are important for the prevention and treatment of iron-deficiency anemia, which is associated with reduced physical functioning, cardiovascular disease, and poor quality of life. Hemodialysis patients are at especially high risk for iron-deficiency anemia, owing to continuous blood losses and supraphysiologic levels of erythropoiesis driven by recombinant human erythropoietin therapy. Unfortunately, the accurate determination of iron status in these patients can be a challenging task, which is made more difficult by inflammation, infections, and the large number of comorbid conditions that can affect commonly used indices of body iron stores. Despite their limitations, transferrin saturation (TSAT) and serum ferritin remain the cornerstones of iron status assessment. Because these values can be altered by a number of non-iron-related factors, it is necessary to go beyond these measures and draw upon additional sources of information to determine the patient's iron status. Other important factors to consider when assessing the need for iron therapy include evidence of underlying inflammatory processes that may block iron mobilization and distort the standard iron indices, the results of alternative iron indices, and the patient's recent history of iron administration. Frequently, the response to a gram of intravenous (i.v.) iron is a safe and effective way to determine the role of iron deficiency in the anemia of the problematic patient. The chronic inflammatory state associated with malnutrition and clinical or subclinical infections substantially increases the risk of misdiagnosing the patient with iron overload and may place the patient at risk of iron deficiency owing to inappropriate withdrawal of i.v. iron therapy. To avoid the risks of withholding iron therapy, the nephrologist must keep this relationship in mind whenever serum ferritin testing suggests replete iron stores, whereas TSAT testing suggests insufficient iron availability.

Related Concept Videos

Microbes and Other Elemental Cycles01:24

Microbes and Other Elemental Cycles

Microbial activity plays a pivotal role in the biogeochemical cycling of iron and manganese, especially at the redox gradients characteristic of stratified aquatic environments. These cycles are driven by microbial transformations between oxidized and reduced forms of the metals, allowing organisms to exploit them for metabolic energy and structural purposes.Iron Cycling Across Redox GradientsIn neutral, oxygen-rich surface waters, iron is predominantly found in its oxidized, insoluble ferric...
Properties of Transition Metals02:58

Properties of Transition Metals

Transition metals are defined as those elements that have partially filled d orbitals. As shown in Figure 1, the d-block elements in groups 3–12 are transition elements. The f-block elements, also called inner transition metals (the lanthanides and actinides), also meet this criterion because the d orbital is partially occupied before the f orbitals.
Ionic Radii03:10

Ionic Radii

Ionic radius is the measure used to describe the size of an ion. A cation always has fewer electrons and the same number of protons as the parent atom; it is smaller than the atom from which it is derived. For example, the covalent radius of an aluminum atom (1s22s22p63s23p1) is 118 pm, whereas the ionic radius of an Al3+ (1s22s22p6) is 68 pm. As electrons are removed from the outer valence shell, the remaining core electrons occupying smaller shells experience a greater effective nuclear...
Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
Corrosion02:49

Corrosion

The degradation of metals due to natural electrochemical processes is known as corrosion. Rust formation on iron, tarnishing of silver, and the blue-green patina that develops on copper are examples of corrosion. Corrosion involves the oxidation of metals. Sometimes it is protective, such as the oxidation of copper or aluminum, wherein a protective layer of metal oxide or its derivatives forms on the surface, protecting the underlying metal from further oxidation. In other cases, corrosion is...
Redox Titration: Overview01:21

Redox Titration: Overview

Redox titration is a chemical analysis technique used to determine the concentration of an unknown substance by measuring the electron transfer in a redox (reduction-oxidation) reaction. The process involves gradually adding a titrant with a known concentration of an oxidizing or reducing agent, to the analyte, the solution with an unknown concentration, until reaching the endpoint, which indicates the completion of the reaction between the two substances. Ensuring the analyte is in a single...