Related Experiment Video
Updated: Aug 7, 2026

Measuring Psoriasis Severity at Home
Published on: March 1, 2024
Measuring quality of life in PSP: the PSP-QoL
1Royal Free and University College Medical School, Department of Clinical Neurosciences, Institute of Neurology, University College London, UK. a.schrag@medsch.ucl.ac.uk
Objective:
To develop a new patient-reported outcome measure for progressive supranuclear palsy (PSP) and to test its psychometric properties.
Methods:
First, the authors generated a pool of potential scale items from in-depth patient interviews. Second, the authors administered these items, in the form of a questionnaire, to a sample of people with PSP and traditional psychometric methods were used to develop a rating scale satisfying standard criteria for reliability and validity. Third, the authors examined the psychometric properties of the rating scale in a second sample.
Results:
In stage 1, a pool of 87 items was generated from 27 patient interviews. In stage 2, a scale with two subscales (physical, 22 items; mental, 23 items), satisfying standard criteria for reliability and validity, was developed from the response data of 225 patients with PSP. In stage 3, the scale was examined in 188 people with PSP. Missing data were low, scores in both subscales were evenly distributed, floor and ceiling effects were small. Reliability was high (Cronbach's alpha 0.93, 0.95; test-retest 0.95, 0.92). Validity was supported by the interscale intercorrelation (0.60), factor analysis, and the magnitude and pattern of correlations with four other rating scales, disease severity, and disease duration. The psychometric properties of the new scale were similar in the United Kingdom and North America, and in clinic- and community-based samples studied.
Conclusions:
The Progressive Supranuclear Palsy Quality of Life scale (PSP-QoL) may be a helpful patient-reported scale for clinical trials and studies in PSP.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Measurement of Blood Pressure
Quality Assurance
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Assessment Sites
Introduction to Statistical Process Control