Study of different atmospheric-pressure interfaces for LC-MS/MS determination of acrylamide in water at sub-ppb levels
Related Experiment Video
Updated: Aug 7, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
José M Marín1, Oscar J Pozo, Juan V Sancho
1Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat s/n E-12071 Castellón, Spain.
Abstract:
A rapid, sensitive and selective method based on LC-MS/MS has been developed for the direct determination of acrylamide residues in water in compliance with the current European Union (EU) 98/83 Drinking Water Directive. Given the high polarity of acrylamide, the application of a rapid on-line solid phase extraction step, commonly used for preconcentrating low analyte levels, was not found to be completely satisfactory. Therefore, an alternative approach based on the use of direct large-volume injection into the LC-MS/MS system has been used. Three atmospheric-pressure interfaces (ESI, APCI and Ion Sabre APCI) were checked to reach the required sensitivity (0.1 microg/l). All three interfaces were tested by analysis of six different water samples (surface water, groundwater, drinking water and three treated water samples) spiked at three concentration levels each (0.1, 1 and 10 microg/l). When using ESI, poor sensitivity and high matrix effects were observed. This situation improved when APCI was used as the interface because no matrix effect was found, although sensitivity was not completely satisfactory. The best results were obtained by interfacing the Ion Sabre APCI; its higher sensitivity for acrylamide (LOD 0.03 microg/l) and the absence of matrix effects recommended its selection. Using this approach, satisfactory recoveries (90-97%) and precision (<12%) were obtained for all water samples studied. Besides, the acquisition of two different MS/MS transitions allowed not only the quantification but also the confirmation of acrylamide in water at concentration levels around 0.1 microg/l.
More Related Videos
04:3213C6-Glucose Labeling Associated with LC-MS: Identification of Plant Primary Organs in Secondary Metabolite Synthesis
Published on: March 22, 2024
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences