Related Experiment Video
Updated: Aug 7, 2026

Temperature-programmed Deoxygenation of Acetic Acid on Molybdenum Carbide Catalysts
Published on: February 7, 2017
At-column heating and a resistively heated, liquid-cooled thermal modulator for a low-resource bench-top GC x GC
Mark Libardoni1, Ernest Hasselbrink, J Hunter Waite
1Department of Chemistry, University of Michigan, Ann Arbor, MI, USA. mark_libardoni@leco.com
Abstract:
A transportable GC x GC instrument is under development for on-site applications that would benefit from the enhanced resolution and powers of detection, which can be achieved by this method. In the present study, a low-resource GC x GC instrument using an electrically heated and liquid-cooled single-stage thermal modulator that requires no cryogenic materials is evaluated. The instrument also uses at-column heating, thus eliminating the need for a convection oven to house the two columns. The stainless-steel modulator tube is coated with PDMS, which can be heated to 350 degrees C for sample injection into the second-dimension column. The modulator is cooled to -30 degrees C by a 100 mL/min flow of PEG by means of a commercial liquid chiller and a small recirculating pump. Resistive heating of the modulator tube is provided by a programmable power supply, which uses a voltage program that results in increasing modulator temperature during an analysis. This, together with more rapid cooling by the use of a liquid cooling medium, results in reduced solute breakthrough following each heating cycle as the modulator cools to a temperature where quantitative trapping resumes. As a result, modulated peak widths at half-height of less than 40 ms are observed. Design and performance details are presented along with chromatograms of gasoline and an essential oil sample.
More Related Videos
10:01Thermal Scanning Conductometry (TSC) as a General Method for Studying and Controlling the Phase Behavior of Conductive Physical Gels
Published on: January 23, 2018
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Instrumentation