Related Experiment Video
Updated: Aug 7, 2026

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Measuring the change in the intermolecular Raman spectrum during dipolar solvation
David F Underwood1, David A Blank
1Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, USA.
Abstract:
We demonstrate a method to directly measure the change in the spectrum of intermolecular solvent fluctuations as a function of time after electronic excitation of a solute, and this method is applied to the dye Coumarin 102 (C102) in acetonitrile. The complete intermolecular response is captured following resonant excitation with time domain third-order Raman spectroscopy. In a previous report, we introduced this method and used it to probe one point in the intermolecular response as a function of time after solute excitation (Underwood, D. F., Blank, D. A. J. Phys. Chem. A 2003, 107 (7), 956). Here we extend this approach to recover the change in the entire intermolecular response as a function of time. To our knowledge the results provide the first direct measurement of the difference in the equilibrated intermolecular response after excitation of a solute and its evolution during a dipolar solvation event. Excitation of C102 results in a significant increase in the solvent-solute interaction due to a large increase in the dipole moment. The observed change in the intermolecular response is consistent with a rapid change in local solvent density, with intermolecular kinetic energy transfer changing the response on longer time scales. Evolution of the response exhibits a strong frequency dependence and suggests changes over longer distances at longer delay times. The measured change in the spectrum of solvent fluctuations represents a direct experimental confirmation of the breakdown of linear response and confirms predictions from molecular dynamics simulations.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
¹H NMR of Labile Protons: Deuterium (²H) Substitution
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
IR Spectrum Peak Intensity: Dipole Moment