The Rhythm ID Going Head to Head Trial (RIGHT): design of a randomized trial comparing competitive rhythm
Ronald D Berger1, Darin R Lerew, Joseph M Smith
1Johns Hopkins Medical Institutions, Baltimore, Maryland, USA.
Background:
The implantable cardioverter defibrillator (ICD) has become primary therapy for the prevention of sudden death. One of the major morbidities of ICD use remains inappropriate therapy for supraventricular arrhythmias (SVA). Detection enhancements have increased therapy specificity, but their impact on inappropriate therapy is not well studied. Moreover, ICD manufacturers have developed unique algorithms to meet this goal, with no previous clinical direct comparisons. RIGHT is a randomized, prospective study that will assess the differential efficacy of ICDs from two different manufacturers. It is the first trial to compare directly competitive ICD rhythm discrimination algorithms on a large scale.
Objective:
The primary objective of this study is to assess arrhythmia discrimination in Guidant versus Medtronic ICDs by comparing the time to first inappropriate therapy after the predischarge visit.
Methods:
The study will enroll approximately 2,000 patients in 100 centers. Patients will be randomized to Guidant or Medtronic using a permuted block design, stratified by center and by single/dual chamber device types. Patients will receive a commercially available Guidant VITALITY 2 family ICD with Rhythm ID or a Medtronic ICD using the Enhanced PR Logic or Wavelet discrimination algorithms, and will be followed according to the schedule shown until a common closing date with a minimum follow-up of 12 months. All events will be reviewed by an independent committee to determine the appropriateness of rhythm classification and therapy delivery.
Conclusion:
RIGHT is the first randomized, large scale, head-to-head comparison of ICD discrimination algorithms.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Dysrhythmias I: Introduction
Dysrhythmias II: Classification of Tachyarrhythmias