Optimization of field-amplified sample injection for analysis of peptides by capillary electrophoresis-mass spectrometry
Related Experiment Video
Updated: Aug 7, 2026

2 in 1: One-step Affinity Purification for the Parallel Analysis of Protein-Protein and Protein-Metabolite Complexes
Published on: August 6, 2018
Yuanzhong Yang1, Reinhard I Boysen, Milton T W Hearn
1Australian Research Council Special Research Centre for Green Chemistry, Monash University, Building 75, Clayton, Victoria, 3800, Australia.
Abstract:
A versatile experimental approach is described to achieve very high sensitivity analysis of peptides by capillary electrophoresis-mass spectrometry with sheath flow configuration based on optimization of field-amplified sample injection. Compared to traditional hydrodynamic injection methods, signal enhancement in terms of detection sensitivity of the bioanalytes by more than 3000-fold can be achieved. The effects of injection conditions, composition of the acid and organic solvent in the sample solution, length of the water plug, sample injection time, and voltage on the efficiency of the sample stacking have been systematically investigated, with peptides in the low-nanomolar (10(-9) M) range readily detected under the optimized conditions. Linearity of the established stacking method was found to be excellent over 2 orders of magnitude of concentration. The method was further evaluated for the analysis of low concentration bioactive peptide mixtures and tryptic digests of proteins. A distinguishing feature of the described approach is that it can be employed directly for the analysis of low-abundance protein fragments generated by enzymatic digestion and a reversed-phase-based sample-desalting procedure. Thus, rapid identification of protein fragments as low-abundance analytes can be achieved with this new approach by comparison of the actual tandem mass spectra of selected peptides with the predicted fragmentation patterns using online database searching algorithms.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...