Related Experiment Video
Updated: Aug 7, 2026

Analyzing Large Protein Complexes by Structural Mass Spectrometry
Published on: June 19, 2010
Monitoring and modeling of protein processes using mass spectrometry, circular dichroism, and multivariate curve
Susana Navea1, Romà Tauler, Anna de Juan
1Chemometrics Group, Department of Analytical Chemistry. Universitat de Barcelona, Av. Diagonal 647, 08028 Barcelona, Spain. susana@apolo.qui.ub.es
Abstract:
Mass spectrometry has recently become one of the major analytical tools to study biomolecular structure and function. Ionization techniques, such as electrospray ionization (ESI), desorb biomolecules from solution to the gas phase keeping practically intact their natural structure. ESI applied to a protein solution produces a mixture of multiply charged ions, the ion charge distribution of which depends on the oligomeric form (mass) and on the protein surface exposed (amount of accommodated charges) of the related protein conformation. ESI-MS provides an efficient way to monitor protein processes; however, the ionic contributions of the different protein conformations involved usually overlap, and the use of chemometric tools is necessary to unravel the information related to the pure conformations that the biomolecule adopts along the process. Multivariate curve resolution-alternating least squares applied to MS-monitored protein processes provides the concentration profiles associated with the different protein conformations occurring during the process and the related pure mass spectra. The concentration profiles, in this context, the ionic contributions, describe the process mechanism and the structural information derived from the pure mass spectra characterizes the involved conformations. Mass spectra can be expressed schematically through percentages of base peak intensity. This chemical transformation compresses significantly the raw spectra and allows for an easier application of natural MS-related constraints, such as the presence of only one maximum, i.e., the base peak of a particular conformation, into the resolution of the pure signals. The combination of mass spectrometry and multivariate curve resolution methods is used to elucidate the mechanism of the pH-induced conformation changes of the bovine beta-lactoglobulin. As a final step, MS data are fused with circular dichroism data and are simultaneously analyzed to ensure and confirm that all the previously detected MS conformations really exist in solution and are an artifact of neither the ionization process nor their chemometric resolution.
More Related Videos
11:49Quantitative Proteomics Workflow using Multiple Reaction Monitoring Based Detection of Proteins from Human Brain Tissue
Published on: August 28, 2021
10:01Combining Chemical Cross-linking and Mass Spectrometry of Intact Protein Complexes to Study the Architecture of Multi-subunit Protein Assemblies
Published on: November 28, 2017
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...