Related Experiment Video
Updated: Aug 7, 2026

Measurement and Analysis of Extracellular Acid Production to Determine Glycolytic Rate
Published on: December 12, 2015
The pH change after HCl titration into resting and stimulated saliva for a buffering capacity test
M Moritsuka1, Y Kitasako, M F Burrow
1Cariology and Operative Dentistry, Department of Restorative Sciences, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan. moritsuka.ope@tmd.ac.jp
Background:
Saliva collection can provide clinical information about individual patients. However, a correlation between ranking buffering capacity using resting and stimulated saliva is still unknown. The aim of this study was to evaluate the pH change after HCl titration into resting and stimulated saliva for a salivary buffering capacity test.
Methods:
Resting and stimulated saliva (by chewing paraffin wax) were collected from 80 patients. After the pH of both saliva samples was measured using a hand-held pH meter, the saliva samples were titrated with 0.1N HCl to evaluate the buffering capacity. Correlations of ranking buffering capacity (high, medium, low) between stimulated saliva and resting saliva with 30 microL HCl titration and between stimulated saliva and resting saliva with 40 microL HCl titration were statistically analysed by Spearman Rank Correlation Test (p < 0.05).
Results:
At 50 microL HCl titration, stimulated saliva buffering capacities were ranked into high (above pH 5.5), medium (pH from 5.5 to 4.5) and low (below pH 4.5). At 30-40 microL HCl titration, the resting saliva buffering capacities were ranked into the same categories. Spearman Rank Correlation indicated significant positive coefficients for the stimulated saliva and resting saliva buffering capacity at 30 microL titration and the stimulated saliva and resting saliva at 40 microL titration.
Conclusion:
Stimulated saliva is more resistant to variation in pH change during HCI titration than resting saliva. Stimulated saliva sampling is a good method to determine buffering capacity during a comprehensive oral health assessment.
More Related Videos
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
10:18Real-Time, Semi-Automated Fluorescent Measurement of the Airway Surface Liquid pH of Primary Human Airway Epithelial Cells
Published on: June 13, 2019
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Titration of Polyprotic Base with a Strong Acid
Calculating pH Changes in a Buffer Solution
Buffers
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of a Strong Acid with a Strong Base