Related Experiment Video
Updated: Aug 7, 2026

Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
Management of sentinel lymph nodes in malignant skin tumors using dynamic lymphoscintigraphy and the
Tsuyoshi Ishihara1, Atsushi Kaguchi, Shigeto Matsushita
1Department of Plastic and Reconstructive Surgery, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-0811, Japan. ishihara@kaiju.medic.kumamoto-u.ac.jp
Background:
The differentiation of true sentinel lymph nodes from nonsentinel lymph nodes is difficult in cases of multiple radiolabeled or dyed lymph nodes.
Methods:
We examined the locations of sentinel lymph nodes in melanoma and other malignant skin tumors by using dynamic lymphoscintigraphy and the single-photon-emission computed tomography/computed tomography (SPECT/CT) combined system.
Results:
Sentinel lymph nodes were detected in 45 of the 53 patients examined using only the ordinary blue dye method (85%), and were detected in all 35 patients examined using the SPECT/CT method (100%). Twenty of the 35 patients mentioned above had one sentinel lymph node. Multiple sentinel lymph nodes were demonstrated in the head and neck areas using the SPECT/CT method. Significant differences (P=0.0015) in the numbers of sentinel lymph nodes were found between the blue dye method only and the SPECT/CT method in the neck area. Popliteal sentinel lymph nodes were recognized in three patients, and cubital sentinel lymph nodes were recognized in two patients. Two patients had plural regional lymph nodes: one had popliteal and groin sentinel lymph nodes, while the other had cubital and axillary sentinel lymph nodes. The probe counts of the popliteus and cubitus were significantly lower (P=0.0241) than the counts in the groin, axilla, and neck areas. Micrometastatic sentinel lymph nodes were recognized in four patients, and two patients had metastases in both sentinel and nonsentinel lymph nodes.
Conclusions:
Dynamic lymphoscintigraphy was useful when we were concerned about cubital and popliteal lymph nodes. The SPECT/CT combined system was useful in recognizing the anatomical location of sentinel lymph nodes before biopsy. The detection rate of sentinel lymph nodes using the SPECT/CT method was always better than that with the blue dye method (P=0.0197).