Related Experiment Video
Updated: Aug 7, 2026

Detection of Detergent-sensitive Interactions Between Membrane Proteins
Published on: March 7, 2018
Electrophoresis of a biocolloid covered with a cation-absorptive membrane
1Department of Chemical Engineering, National Chung Cheng University, Chia-Yi, Taiwan 62102, Republic of China. chmyck@ccu.edu.tw
Abstract:
The electrophoretic behavior of a biocolloid covered with a charged membrane is theoretically analyzed in the present study. Here, the influences of nonuniformly distributed fixed groups, absorption of cations by fixed original functional groups, variation in dielectric constant in the electrophoretic system, and ionic sizes are considered. The results of numerical simulation suggest that a larger absolute value of the electrophoric mobility of biocolloids could be generated by larger membrane electricity. The absolute value of the electrophoric mobility for the nonlinear distribution of the fixed groups is larger than that for the linear distribution of the fixed groups. The absolute value of the electrophoric mobility increases with (1) the concentration of total fixed groups, (2) the cation-absorption equilibrium constant, (3) the nonuniform feature index for functional-groups distribution, (4) the dielectric constants of the inner uncharged membrane zone for only mobile cationic charge and for both mobile cationic and anionic charge, and (5) the effective size of the cations. An increase in the absolute value of the electrophoric mobility can also be resulted from a decrease in the following parameters: (1) the friction coefficient of the biocolloidal membrane phase, (2) the membrane thickness, (3) the dielectric constant of space for all charge and of outer uncharged membrane zone, (4) the effective sizes of anions and fixed groups, and (5) the number of cations and the fixed original functional groups involved in the formation of a cation-functional group complex.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Capillary Electrophoresis: Instrumentation
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...