Related Experiment Video
Updated: Aug 7, 2026

Testing of all Six Semicircular Canals with Video Head Impulse Test Systems
Published on: April 18, 2019
[Cervicocephalic relocation test: a study of performance stability]
N Pinsault1, J Vaillant, G Virone
1Centre de recherche et d'innovation en kinésiologie, kinésiopathologie et kinésithérapie (CRIK3), école de kinésithérapie du CHU de Grenoble, institut universitaire professionnalisé en ingénierie de la santé, BP 217, 38049 Grenoble cedex 09, France.
Objective:
The purpose of the present experiment was to determine the reliability of the cervicocephalic relocation test (CRT).
Methodology:
Thirteen young healthy adults were recruited to undergo a CRT test-retest. The test-retest reliability was determined by repeatedly measuring CR to a neutral position after active movement, with trials approximately 1 hour apart. Each CRT involved 20 CRs to a natural head position, 10 repositioning after right head rotation, and 10 repositioning after left head rotation (with the order of rotation sides randomized). The performance score for each subject for each CRT was the mean of the errors made during the 20 relocations (in degrees).
Study Results:
The mean rate of error of the first and second trials was 3.2+/-1.1 degrees and 2.9+/-0.9 degrees, respectively. The intra class correlation coefficient was 0.81, and the standard error of measurement 0.90 degrees.
Conclusion:
CRT testing supports evidence of reliable cervicocephalic performance stability in healthy young adults. CRT shows promise as a relevant tool of assessment in head and neck proprioception.