Control of electroosmotic flow by polymer coating: effects of the electrical double layer

R Qiao1

  • 1Department of Mechanical Engineering, College of Engineering and Science, Clemson University, Clemson, SC 29634, USA. rqiao@clemson.edu

Related Concept Videos

The Electrical Double Layer01:30

The Electrical Double Layer

In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
Theory of Strong Electrolytes01:23

Theory of Strong Electrolytes

The interionic forces of the strong electrolytes depend on the solvent's dielectric constant, which is the ability of a solvent to store electrical energy, based on its polarizability. and the solution's concentration. In high-dielectric solvents and in dilute solutions, weak electrostatic forces keep ions apart. However, in low-dielectric solvents or concentrated solutions, stronger interionic forces may cause ions to pair up as ionic doublets despite being fully ionized. The theory of strong...
Debye–Huckel–Onsager Conductance Equation01:28

Debye–Huckel–Onsager Conductance Equation

The Debye-Hückel-Onsager equation is a cornerstone of physical chemistry, providing a method to determine the molar conductance (Λm) and molar conductance at infinite dilution (Λ°m) for uni-univalent electrolytes.Uni-univalent electrolytes are electrolytes that dissociate in solution to produce one cation with a +1 charge and one anion with a –1 charge per formula unit.This equation addresses two crucial phenomena: the asymmetry effect and the electrophoretic effect. According to this equation,...
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Processes at Electrodes01:30

Processes at Electrodes

The electrode interacts with ions in the electrolyte solution at its interface. The rate of oxidation and reduction depends on the speed at which electrons can transfer through this interface. As ions attach to or leave the electrode surface, the electrode acquires a charge, and an electrical potential forms across the interface, making the process more difficult to reach equilibrium. The charge on the electrode affects the local ion concentrations in the solution, though thermal motion...