Related Experiment Video
Updated: Aug 6, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT
Paul E Kinahan1, Adam M Alessio, Jeffery A Fessler
1Department of Radiology, University of Washington, 200 Old Fisheries Center, Box 35 7987, Seattle, WA 98195, USA. kinahan@u.washington.edu
Abstract:
We hypothesize that improved quantification for PET imaging of high atomic number materials can be achieved by combining low-dose x-ray imaging with dual energy CT for PET attenuation correction. Improved quantification of tracer uptake will lead to improved patient outcomes by providing more accurate information for therapeutic choices. Accurate PET/CT measurements of early response will be critical in determining the best cancer therapy option for each patient in a timely manner and in sparing patients the morbidity and cost of ineffective treatments. We first evaluate the potential errors in PET images arising from CT-based attenuation correction when iodine-based contrast is incorrectly classified as bone when forming the linear attenuation coefficient image. We then investigate two methods of reducing errors in the linear attenuation image: an approximate, but fast, hybrid classification/scaling algorithm and a model-based dual-energy CT method that incorporates the polyenergetic spectrum and a noise model in an iterative reconstruction method. Both methods are shown to reduce errors in the estimated linear attenuation coefficient image, but require further study to determine the effects of noise propagation if low-dose CT scans are used for the estimation of the linear attenuation image.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...