Liquid chromatography-mass spectrometry in bioanalysis: some applications and a new approach for non-volatile buffer
J van der Greef1, W M Niessen, U R Tjaden
1Division of Analytical Chemistry, Center for Bio-Pharmaceutical Sciences, Leiden University, P.O. Box 9502, 2300 RA Leiden, The Netherlands.
Abstract:
Combined liquid chromatography mass spectrometry (LC/MS) is still a rapidly developing area. The advantages and limitations of the most important interfaces, i.e. the moving belt interface, the thermospray interface, and continuous-flow fast atom bombardment, are discussed from a bioanalytical point of view. The discussion is underlined by two bioanalytical applications of LC/MS using a moving belt interface. The first example is the identification of unknown compounds in alkaline extracts of post-mortem human urine and plasma. The second example is actually concerned with a new approach in LC/MS: phase-system switching using a short column between the LC chromatography and the moving belt interface. The perspectives of the latter are outlined.