JPEG2000 compression of thin-section CT images of the lung: effect of compression ratio on image quality
Helmut Ringl1, Ruediger E Schernthaner, Alexander A Bankier
1Department of Radiology, University Hospital Vienna, AKH Wien, Währinger Gürtel 18-20, A-1090, Vienna, Austria. helmut.ringl@meduniwien.ac.at
Purpose:
To assess retrospectively the effect of the Joint Photographic Experts Group 2000 (JPEG2000) compression ratio on the quality of thin-section computed tomographic (CT) images.
Materials And Methods:
In this institutional review board-approved investigation (protocol 238/2004), thin-section CT images were subjected to irreversible JPEG2000 compression by using five compression ratios (3:1, 5:1, 7:1, 9:1, and 11:1). Three radiologists independently evaluated 60 thin-section CT images, of various diseases, that were obtained with single-detector (weighted dose index, 14.4 mGy) and multidetector (weighted dose index, 9.8 mGy) CT. Toggling between the original and compressed images, readers had to identify the original image by using a forced-choice two-alternative model and to subjectively rank the quality of what they believed to be the compressed image. To assess the reader's ability to distinguish the compressed from the original image, a binomial test was used. Bonferroni correction was applied for all multiple tests.
Results:
Images compressed with a ratio of 3:1 were not distinguishable from original images (P > .2 for all readers). With use of the 5:1 ratio, minor differences in appearance between the compressed and original images were seen by one of the three readers. With use of higher compression ratios (>/=7:1), all readers (P < .001) recognized the original image. The quality of more than 90% of the images compressed with a 7:1 or higher ratio was substantially degraded. Single-detector and multidetector CT results were not significantly different.
Conclusion:
The highest ratio that yielded visually lossless compression of thin-section CT images was 3:1. With the 5:1 ratio, there was minor image quality loss, while use of higher compression ratios (>/=7:1) caused substantial degradation of image quality and potential loss of diagnostic information.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...