Related Experiment Video
Updated: Aug 6, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
GC-MS-MS determination of gamma-hydroxybutyrate in blood and urine
Richard Paul1, Lolita Tsanaclis, Robert Kingston
1University of Glamorgan, Pontypridd, CF37 1DL, Wales. richpaul@talk21.com
Abstract:
A gas chromatographic-tandem mass spectrometric (GC-MS-MS) method for determining trace concentrations of gamma-hydroxybutyrate (GHB) in blood and urine has been developed. Multiple reaction monitoring was used to detect parent and daughter ions of GHB, 233 and 147, respectively, following liquid-liquid extraction with acetonitrile and derivatisation with N,O-bis[trimethylsilyl]trifluoroacetamide (BSTFA). Deuterated GHB was used as an internal standard. The assay produced excellent linearity and sensitivity without conversion to gamma butyrolactone. The lower limit of quantitation (LLOQ) in 50 microL of sample was 2.5 microg/mL. The expanded uncertainty values for intra- and interassay results were +/- 0.097 and +/- 0.123 ng/mL at a confidence level of 95% for blood and urine, respectively. Endogenous concentrations of GHB were found to be in the range of 0.3 to 6 microg/mL in urine and 0.5 to 2.3 microg/mL in blood, confirming previously suggested cut-off values for forensic analysis.