[Determination of the aortic pulse wave velocity in 545 healthy subjects]
Xiao-ning Liu1, Hai-qing Gao, Bao-ying Li
1Department of Geriatrics, Qi-Lu Hospital of Shandong Univercity, Jinan 250012, China.
Objective:
To understand the aortic pulse wave velocity (PWV) in mid-aged and elderly populations and to study the correlation between gender and PWV and the tendency of PWV on different age groups.
Methods:
According to the clinical trial guideline, we selected 545 healthy subjects (age, 31-85 years, 395 men and 150 women), and measured carotid-femoral PWV, using Complior.
Results:
The average value of PWV in Chinese healthy subjects was 11.62 +/- 2.97 m/s. There was no significant difference in the PWV values between males and females who were older than 40 years, but the values of PWV were lower in females than in males in the 30-39 year-old group. PWV was positively correlated with age. In the present study, the reference values of PWV were established in the different age groups, based on the regression equations between PWV and age.
Conclusion:
Aortic pulse wave velocity seemed to be influenced by age but hardly influenced by gender in healthy subjects, so that the reference value of PWV should be established according to the different age groups. When aorta got stiffer, the value PWV got larger accordingly when age was increasing.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse