Competitive immobilization of multiple component chlorinated solvents by cyclodextrin derivatives
Jung-Seok Yang1, Kitae Baek, Tae-Soon Kwon
1Department of Chemical and Biomolecular Engineering, KAIST, 373-1 Guseong-dong, Yuseong-gu, Daejeon 305-701, Republic of Korea.
Abstract:
Immobilization of chlorinated solvents with hydropropyl and methyl cyclodextrins (CDs) was observed by head-space analysis to obtain the stability constants in single and multiple component systems. In each single component system, the highest stability constant was 0.299 mM(-1) for perchloroethylene (PCE) by methyl-beta-cyclodextrin (M-beta-CD), 0.136 mM(-1) for trichloroethylene (TCE) by M-beta-CD, 0.106 mM(-1) for cis-dichloroethylene (cis-DCE) by hydropropyl-alpha-cyclodextrin, and 0.090 mM(-1) for trans-dichloroethylene (trans-DCE) by M-beta-CD. When HP-beta-CD and M-beta-CD were used, the stability constants of PCE and TCE increased and those of DCEs decreased in a multiple component system. Differences in stability constants of single and multiple component systems thus should be important parameters when cyclodextrins are applied to solubilization of multiple chlorinated solvents.
More Related Videos
10:10Transport Properties of Ibuprofen Encapsulated in Cyclodextrin Nanosponge Hydrogels: A Proton HR-MAS NMR Spectroscopy Study
Published on: August 15, 2016
09:22Self-assembling Morphologies Obtained from Helical Polycarbodiimide Copolymers and Their Triazole Derivatives
Published on: February 7, 2017
Related Concept Videos
Ion Exchange
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...
Entropy and Solvation
Extraction: Advanced Methods
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...