Quantitative measurement of speech sound distortions due to inadequate dental mounting
G E Drăgănescu1, C Sinescu, D Dodenciu
1Department of Mechanics and Vibrations, Polytechnic University of Timişoara, Romania. ghed@mec.utt.ro
Abstract:
In this paper, the most adequate quantitative parameters are sought that reflect the dependence of speech sound distortions on the correct position of dental mountings. We suggest the Hurst fractal exponent and some parameters calculated from the Paul wavelet transform of speech sound are useful as quantitative parameters. The investigations are focussed on the alterations of the first /s/ phoneme when the patient produces the Sisyphe sound. The results will be useful to obtain a rigorous, computer assisted method to establish (design) the optimal parameters of prosthetic mounts in order to ensure best speech quality.